Engineering

Fire Dampers Services for Industrial Projects

Fire Dampers Services for Industrial Projects visual placeholder - Sagiant Piping Industries
Engineering visual
StandardsASTM / ASME / EN
Size RangeProject sizes
MaterialsGalvanized steel (GI), SS 304…
Ratings1.5 hour & 3 hour (per…
DocumentsMTC / TPI

Basic Description

Sagiant Piping Industries supplies fire dampers for HVAC ducts and wall/floor penetrations — curtain-blade (folding) and multi-blade dynamic fire dampers in galvanized steel with stainless options, rated for 1.5-hour and 3-hour fire resistance. Fire dampers close on a 72°C (165°F) fusible link or thermal release and are built and tested to UL 555, BS EN 1366-2, BS 476 Part 20 and AMCA 540 with installation sleeves, breakaway connections and access doors, supplied with fire-rating certificates and full project documentation.

Fire Dampers manufacturer stockist supplier - Sagiant Piping Industries
Technical Data

Fire damper types, materials, sizes and fire-rating reference data

Fire dampers for duct penetrations of fire-rated walls and floors. Sagiant Piping Industries / SPI Steel keeps damper types, construction materials, sizes, standards and fire-rating data on one page for HVAC and life-safety teams.

Technical Specification

ParameterSpecification
Product TypeCurtain-blade (folding) & dynamic multi-blade fire dampers
MaterialGalvanized steel (GI), SS 304 / 316 options
Fire Rating1.5 hour & 3 hour (per tested assembly)
Release72°C / 165°F fusible link (also 141°C); thermal / electro-thermal
BladeFolding curtain or airfoil / dynamic blades
Frame / SleeveMounting sleeve with breakaway duct connection
AccessInspection / reset access door
StandardsUL 555, EN 1366-2, BS 476-20, AMCA 540

Construction Materials

MaterialGrade / SpecTypical UseFinish
Galvanized steel (GI)IS 277 / ASTM A653, Z180–Z275Frame & blades (standard)Pre-galvanized
Cold-rolled steel (CRCA)IS 513 / ASTM A1008Frames, linkage partsPowder coated
Extruded aluminium6063-T5Light-weight blades & frameMill / anodized
Stainless steel304 / 316 (ASTM A240)Cleanroom, kitchen-exhaust, corrosive2B / brushed

Fire Damper Types

TypeDescriptionTypical Use
Curtain-blade (Type A / B)Folding blade stack springs shutStatic-system fire walls & floors
Dynamic multi-bladeAirfoil blades close under airflowSystems running during fire (dynamic)
Combination fire / smokeUL 555 + UL 555S ratedWhere both fire & smoke control are needed
Round fire damperCurtain blade in spigot frameCircular duct penetrations

Standards & Specifications

ScopeApplicable Standards
Fire resistanceUL 555, BS EN 1366-2, BS 476 Part 20 / 22
ClassificationEN 13501-3 (EI rating), AMCA 540
ConstructionSMACNA, NFPA 90A, project specification
MaterialASTM A653 (GI), ASTM A240 (SS)

Testing, Inspection & Documentation

Test / DocumentDetail
Fire ratingUL 555 / EN 1366-2 furnace test, EI classification
ReleaseFusible-link / actuator closure function test
CycleOpen/close operation & spring-closure check
DimensionalFrame, sleeve & blade-pack check
DocumentationFire-rating certificate, installation manual, dispatch list

Applications & Industries Served

HVAC & VentilationCleanrooms & PharmaHospitals & HealthcareCommercial BuildingsData CentersHospitality & MallsAirports & MetroIndustrial & Process

Available Forms, Sizes & Range

Share wall/floor fire rating, duct size and static/dynamic system type to select the correct tested assembly.

ItemSize RangeWall / Thickness / RatingStandard
Rectangular fire damper150 x 150 to 1200 x 1200 mm (modular)1.2–1.6 mm GIUL 555 / EN 1366-2
Round fire damper100–630 mm diaGIUL 555

Frequently Asked Questions

What fire ratings are available?

Fire dampers are supplied for 1.5-hour and 3-hour fire resistance per the tested UL 555 / EN 1366-2 assembly.

How does a fire damper close?

A 72°C (165°F) fusible link, or a thermal/electro-thermal release, melts in a fire and lets the curtain or spring-loaded blades close and seal the duct.

What is the difference between static and dynamic fire dampers?

Static (curtain-blade) dampers are for systems that shut down in fire; dynamic dampers are tested to close against airflow when the fan keeps running.

Are combination fire and smoke dampers available?

Yes — combination dampers rated to both UL 555 and UL 555S control fire and smoke through a single unit.

What documentation is provided?

Fire-rating test certificates, installation sleeves and instructions, and project inspection records.

Scope of Work

The fire dampers scope can include project review, fabrication support, dimensional coordination, inspection documentation and dispatch support for industrial installations.

Applications

  • Oil & gas, refinery, petrochemical and process plants
  • Power, boiler, heat exchanger, water and utility systems
  • EPC projects, OEM fabrication, maintenance shutdowns and infrastructure works
  • Corrosion, high-temperature, pressure, HVAC or custom fabrication service depending on grade and product form

For related project work, review Custom Fabrication, Contact Sales or for technical assistance.

Types of Products

TypeDescription
Fabricated AssembliesBuilt as per drawing and site requirement
Sheet Metal ProductsDoors, dampers, diffusers and HVAC items
Tanks / SkidsPrefabricated tanks and supporting assemblies
Custom ItemsProject-specific metal fabrication

Available Forms

  • Doors and frames
  • Tanks
  • Duct accessories
  • Diffusers
  • Dampers
  • Clean room components
  • Skids
  • Custom assemblies
Project Workflow

From requirement to dispatch

A drawing-led, inspection-backed process for engineered and fabricated supply — the same discipline on every project.

  1. 01

    Requirement Review

    Drawing, BOQ, specification and project scope reviewed to confirm feasibility.

  2. 02

    Design & Specification

    Material, method, tolerance and finish aligned to the applicable standard.

  3. 03

    Fabrication Planning

    Production planned with inspection and test points built into the sequence.

  4. 04

    Inspection & QA

    Dimensional and visual inspection against drawing, with documentation as required.

  5. 05

    Packing & Dispatch

    Tagging, packing and dispatch documentation for on-time project delivery.

FAQ

Frequently Asked Questions

What materials does Sagiant Piping Industries supply?

Sagiant Piping Industries can supply stainless steel, carbon steel, alloy steel, duplex, super duplex and nickel alloy products subject to project requirement.

Do you provide MTC and test certificates?

MTC, test certificates, heat number traceability and inspection documents can be coordinated based on the material, standard and project scope.

Can Sagiant supply as per project BOQ?

Yes. The team can review BOQs, line lists, drawings and specifications to support pipes, fittings, flanges, fasteners and fabricated items.

Do you support third-party inspection?

Third-party inspection, PMI and dimensional inspection support can be arranged when required by the enquiry or project documentation.

Can you work from drawings or site requirements?

Engineering and fabrication enquiries can be reviewed from drawings, BOQs, approved samples or project specifications.

Do you provide custom fabrication services for industrial projects?

Custom fabrication support is available for industrial assemblies, tanks, duct accessories, clean room items and project-specific metal works.

Procurement Flow

A controlled path from requirement to delivery support

A technical RFQ flow built for engineers, QA teams and project buyers who need clear standards, traceability and dispatch documentation.

01

Requirement Submission

Share product, grade, size, class, quantity, drawing and delivery location.

02

Technical Review

Review standards, specifications, missing inputs and service conditions.

03

Material Selection

Align stainless, carbon, alloy, duplex, titanium or nickel alloy grades.

04

Quotation & Approval

Confirm commercial scope, documents, inspection needs and timelines.

05

Production / Sourcing

Coordinate manufacturing, stock sourcing or fabrication as per scope.

06

Quality Inspection

Manage dimensional checks, MTC review, PMI or third-party inspection.

07

Dispatch & Documentation

Prepare packing, tagging, test certificates and dispatch documents.

08

Delivery Support

Support delivery coordination, document handover and project closure.

Product Finder

Find the right product path

Choose what you need and jump directly to the correct product, material or engineering section.

Pipes & TubesStart with product family, size, schedule, grade and quantity.
Open Recommended Page
Interactive industrial piping product hotspots
Pipes & TubesStart with NPS, OD, schedule, grade, end finish and quantity.
Stainless Steel

304/L, 316/L, 321, 347 and 904L for corrosion-resistant piping, fittings, flanges and fabrication.

View stainless steel
Carbon Steel

ASTM A106, A53, A105, API 5L and IS 2062 for pressure, utility and structural supply.

View carbon steel
Duplex / Super Duplex

UNS S31803, S32205, S32750 and S32760 for chloride, offshore and desalination service.

View duplex grades
High Nickel Alloys

Inconel, Monel, Hastelloy, Incoloy and Nickel 200/201 for severe corrosion and heat service.

View nickel alloys